PRODUCT MODEL NUMBERS
UXW7230BSS
Electrical: A 120 volt, 60 Hz., AC only, 15-amp, fused electrical
circuit is required.
30" (76.2 cm) Wall-Mount Canopy Range Hood
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
Vent System
Vent Piece 6" (15.2 cm) Round
45° elbow 2.5 ft
(0.8 m)
90° elbow 5.0 ft
(1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
The following example falls within the maximum recommended vent
length of 35 ft (10.7 m).
1 - 90° elbow = 5.0 ft (1.5 m)
1 - wall cap = 0.0 ft (0.0 m)
8 ft (2.4 m) straight = 8.0 ft (2.4 m)
Length of system = 13.0 ft (3.9 m)
VENTING METHODS
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside,
the hood can be used in the non-vented (recirculating) version, by
fitting a charcoal filter and the deflector. Fumes and vapors are recycled
through the top grille. See the “Assistance or Service” section for
information on ordering.
Roof Venting Wall Venting Non-vented
(recirculating)
A. Roof cap
B. 6" (15.2 cm)
round vent
A. Wall cap
B. 6" (15.2 cm)
round vent
A. Deflector
B. 6" (15.2 cm)
round vent
A
A
B
B
B
A
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
PRODUCT DIMENSIONS
*For non-vented (recirculating) installations
**For vented installations
30" (76.2 cm)
10"
(25.4 cm)
20" (50.8 cm)
14¹⁄₈"
(35.9 cm)
7¹⁄₄"
(18.4 cm)
8¹⁄₈"
(20.6 cm)
*28⁷⁄₈" (73.3 cm) min.
42¹⁄₁₆" (106.8 cm) max.
**28³⁄₈" (72.0 cm) min.
38" (96.5 cm) max.
1 " (3.8 cm)
Ref. W10646401B
12/8/14
Page 1 of 2
Example vent system
90 elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
Przeglądanie stron 0
1 2

Podsumowanie treści

Strona 1 - Example vent system

PRODUCT MODEL NUMBERSUXW7230BSSElectrical: A 120 volt, 60 Hz., AC only, 15-amp, fused electricalcircuit is required.30" (76.2 cm) Wall-Mount Cano

Strona 2

Because Whirlpool Corporation policy includes a continuous commitment to improveour products, we reserve the right to change materials and specificati

Komentarze do niniejszej Instrukcji

Brak uwag