Maytag W10131619A Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Elektryczne suszarki do prania Maytag W10131619A. Maytag W10131619A User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - ELECTRIC DRYER

ELECTRIC DRYERUSE & CARE GUIDE/INSTALLATION INSTRUCTIONSVISIT OUR WEBSITE AT WWW.MAYTAG.COM.W10131619A

Strona 2 - DRYER SAFETY

104-wire connection: Direct WireIMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire conn

Strona 3 - WARNING:

114. Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends toget

Strona 4 - INSTALLATION INSTRUCTIONS

12When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked en

Strona 5 - Electrical Requirements

134. Tighten strain relief screws.5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.6. Connect a

Strona 6 - 3-wire receptacle (10-30R)

14ExhaustRecommended hood styles are shown here. 4"(102 mm) 4"(102 mm)BAA. Louvered hood styleB. Box hood styleThe angled hood styl

Strona 7 - Electrical Connection

15Alternate installations for close clearancesVenting systems come in many varieties. Select the type best for your installation. Two close-clearance

Strona 8 - C. Strain relief threads

16Install Leveling LegsWARNINGExcessive Weight HazardUse two or more people to move and install dryer.Failure to do so can result in back or other inj

Strona 9

177. Attach door hinges to dryer door so that the larger hole is at the bottom of the hinge. 8. Remove door strike (E) from cabinet. Use a small,

Strona 10 - (127 mm)

18DRYER USEStarting Your DryerWARNINGExplosion HazardKeep ammable materials and vapors, such as gasoline, away from dryer.Do not dry anything that ha

Strona 11 - 3½"

19To restart your dryer1. Close the door. 2. Select a new cycle and temperature (if desired). 3. Push the START button.Drying Rack OptionUse the Dryin

Strona 12 - Optional 3-wire connection

2TABLE OF CONTENTSDRYER SAFETY...

Strona 13 - Venting Requirements

203. Wet a nylon brush with hot water and liquid detergent. Scrub lint screen with the brush to remove residue buildup.4. Rinse screen with hot water.

Strona 14 - Plan Vent System

21TROUBLESHOOTINGFirst try the solutions suggested here or visit our website and reference FAQs (Frequently Asked Questions) to possibly avoid the cos

Strona 15 - Install Vent System

22 Is the exhaust vent diameter the correct size? Use 4" (102 mm) diameter vent material. Is the dryer located in a room with temperature belo

Strona 16 - Install Leveling Legs

23ASSISTANCE OR SERVICEIf you need assistance or service, first see the “Troubleshooting” section. Additional help is available by contacting the plac

Strona 17 - Complete Installation

W10131619A© 2008All rights reserved.®Registered trademark/™ Trademark of Maytag Corporation or its related companies. 7/08Printed in U.S.A.

Strona 18 - DRYER USE

IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of re, electric shock, or injury to persons when using the dryer, follow ba

Strona 19 - DRYER CARE

4INSTALLATION INSTRUCTIONSTools and PartsGather the required tools and parts before starting installation. Read and follow the instructions provided w

Strona 20 - Vacation and Moving Care

(705 mm)29"(736.6 mm)(1100mm)(578 mm)5Dryer Dimensions*Most installations require a minimum 5" (127 mm) clearance behind the dryer fo

Strona 21 - TROUBLESHOOTING

6 A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohib

Strona 22 - Excessive Weight Hazard

7Electrical ConnectionPower Supply CordWARNINGFire HazardUse a new UL listed 30 amp power supply cord. Use a UL listed strain relief. Disconnect power

Strona 23 - ACCESSORIES

8 Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain

Strona 24 - Printed in U.S.A

94-wire connection: Power Supply Cord IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wir

Komentarze do niniejszej Instrukcji

Brak uwag